NCT05601544

The Effects of Contact Lenses With UV/HEV-Filter on Visual Function

Completed NA Results posted Last updated 27 April 2025
What this trial tests

NA trial testing ACUVUE OASYS 1-Day in Visual Acuity in 145 participants. Completed in 17 November 2023.

Timeline
9 December 2022
Primary endpoint
17 November 2023
17 November 2023

Quick facts

Lead sponsorJohnson & Johnson Vision Care, Inc.
PhaseNA
StatusCompleted
Study typeINTERVENTIONAL
Allocationrandomized
Designcrossover
Maskingdouble
Primary purposetreatment
Enrollment145
Start date9 December 2022
Primary completion17 November 2023
Estimated completion17 November 2023
Sites1 location across United States

Drugs / interventions tested

Conditions studied

Sponsor

Johnson & Johnson Vision Care, Inc. — full company profile →

Who can join

Adults 18 to 70, any sex, with Visual Acuity. Patients with the condition only — healthy volunteers not accepted.

Results — posted to ClinicalTrials.gov

Per-arm endpoint measurements with 95% confidence intervals where reported. Source: trial results section.

Visual Range at Phase 1 Primary · Approximately 15 minutes post lens fitting

Visual range is defined as the log relative energy of simulated haze needed to obscure an otherwise high contrast grating target. Better visual range is indicated by a higher log-relative energy (LRE) of simulated haze (more haze) to obscure an otherwise highly visible target.

GroupValue95% CI
Senofilcon A (Test) Sphere Strata - Phase 13.232± 0.1658
Senofilcon A (Control) Sphere Strata - Phase 13.049± 0.2101
Senofilcon A (Test) Multifocal Strata - Phase 13.287± 0.1824
Senofilcon A (Control) Multifocal Strata - Phase 13.167± 0.1072
Visual Range at Phase 2 Primary · Approximately 15 minutes post lens fitting

Visual range is defined as the log relative energy of simulated haze needed to obscure an otherwise high contrast grating target. Better visual range is indicated by a higher log-relative energy (LRE) of simulated haze (more haze) to obscure an otherwise highly visible target.

GroupValue95% CI
Senofilcon A (Test) Sphere Strata - Phase 23.377± 0.1489
Senofilcon A (Control) Sphere Strata - Phase 23.156± 0.1181
Senofilcon A (Test) Multifocal Strata - Phase 23.181± 0.1649
Senofilcon A (Control) Multifocal Strata - Phase 23.020± 0.1412
Motion Detection at Phase 1 Primary · Approximately 15 minutes post lens fitting

Motion detection is defined as the distance needed (in mm) to determine that a test light has moved from a standard position. Better motion detection is indicated by a smaller distance needed to detect that movement has occurred.

GroupValue95% CI
Senofilcon A (Test) Sphere Strata - Phase 11.725± 1.3575
Senofilcon A (Control) Sphere Strata - Phase 12.881± 1.9824
Senofilcon A (Test) Multifocal Strata - Phase 13.229± 2.3248
Senofilcon A (Control) Multifocal Strata - Phase 12.716± 3.1286
Brightness Perception at Phase 1 Primary · Approximately 15 minutes post lens fitting

Brightness perception is defined as the log- relative energy needed to match a standard stimulus to a natural scene, across 10 different projected scenes. The perception of brighter image is indicated by a higher log-relative energy (LRE) needed to match the initially dim standard to the target.

GroupValue95% CI
Senofilcon A (Test) Sphere Strata - Phase 11.109± 0.0909
Senofilcon A (Control) Sphere Strata - Phase 11.081± 0.1494
Senofilcon A (Test) Multifocal Strata - Phase 11.101± 0.1388
Senofilcon A (Control) Multifocal Strata - Phase 11.041± 0.2222
Motion Detection at Phase 2 Secondary · Approximately 15 minutes post lens fitting

Motion detection is defined as the distance needed (in mm) to determine that a test light has moved from a standard position. Better motion detection is indicated by a smaller distance needed to detect that movement has occurred.

GroupValue95% CI
Senofilcon A (Test) Sphere Strata - Phase 23.894± 2.6800
Senofilcon A (Control) Sphere Strata - Phase 24.288± 2.9575
Senofilcon A (Test) Multifocal Strata - Phase 23.499± 2.4146
Senofilcon A (Control) Multifocal Strata - Phase 23.3376± 2.3750
Brightness Perception at Phase 2 Secondary · Approximately 15 minutes post lens fitting

Brightness perception is defined as the log- relative energy needed to match a standard stimulus to a natural scene, across 10 different projected scenes. The perception of brighter image is indicated by a higher log-relative energy (LRE) needed to match the initially dim standard to the target.

GroupValue95% CI
Senofilcon A (Test) Sphere Strata - Phase 21.356± 0.0670
Senofilcon A (Control) Sphere Strata - Phase 21.222± 0.0615
Senofilcon A (Test) Multifocal Strata - Phase 21.360± 0.0832
Senofilcon A (Control) Multifocal Strata - Phase 21.219± 0.0843

Sponsor's own description

This is a 2-phase, single-site, non-dispensing, randomized, controlled, double-masked, 2x2 crossover study to objectively measure potential benefits of a new UV/HEV filter using psychophysical testing techniques.

Publications & conference data

1 peer-reviewed publication reference this trial (live from Europe PMC):

  1. The effects of a HEV-filtering contact lens on the brightness of natural images.
    Hammond BR, Buch JR, Martin P, Shamp W, et al · · 2025 · cited 2× · PMID 41159572 · DOI 10.1111/opo.70035

Verify or expand the search:

Other recruiting trials for Visual Acuity

Currently open trials in the same condition.