Last reviewed · How we verify

NCT04585646

A Two-Week Crossover Dispensing Evaluation Of Orion Daily Wear Soft Contact Lens

Completed NA Results posted Last updated 10 May 2022
What this trial tests

NA trial testing Orion daily disposable contact lens in Myopia in 64 participants. Completed in 31 December 2020.

Timeline
14 September 2020
Primary endpoint
30 November 2020
31 December 2020

Quick facts

Lead sponsorCooperVision, Inc.
PhaseNA
StatusCompleted
Study typeINTERVENTIONAL
Allocationrandomized
Designcrossover
Maskingdouble
Primary purposetreatment
Enrollment64
Start date14 September 2020
Primary completion30 November 2020
Estimated completion31 December 2020
Sites1 location across United States

Drugs / interventions tested

Conditions studied

Sponsor

CooperVision, Inc.

Who can join

Adults 18 to 55, any sex, with Myopia. Patients with the condition only — healthy volunteers not accepted.

Results — posted to ClinicalTrials.gov

Per-arm endpoint measurements with 95% confidence intervals where reported. Source: trial results section.

Subjective Response for Vision Satisfaction Primary · Baseline - After 10 minutes of lens dispense

Subjective Response for Vision Satisfaction assessed on 7-point Likert (Very satisfied, Satisfied, Somewhat satisfied, Neither Satisfied nor Dissatisfied, Somewhat Dissatisfied, Dissatisfied, Very Dissatisfied)

Very satisfied
GroupValue95% CI
Orion24
Gemini28
Satisfied
GroupValue95% CI
Orion30
Gemini24
Somewhat Satisfied
GroupValue95% CI
Orion4
Gemini7
Neither
GroupValue95% CI
Orion1
Gemini0
Somewhat Dissatisfied
GroupValue95% CI
Orion0
Gemini0
Dissatisfied
GroupValue95% CI
Orion0
Gemini0
Very Dissatisfied
GroupValue95% CI
Orion0
Gemini0
Subjective Response for Overall Vision Satisfaction Primary · 2 Weeks

Subjective Response for Vision satisfaction assessed on 7-point Likert (Very satisfied, Satisfied, Somewhat satisfied, Neither Satisfied nor Dissatisfied, Somewhat Dissatisfied, Dissatisfied, Very Dissatisfied)

Very satisfied
GroupValue95% CI
Orion26
Gemini28
Satisfied
GroupValue95% CI
Orion22
Gemini24
Somewhat Satisfied
GroupValue95% CI
Orion7
Gemini5
Neither
GroupValue95% CI
Orion0
Gemini1
Somewhat Dissatisfied
GroupValue95% CI
Orion3
Gemini1
Dissatisfied
GroupValue95% CI
Orion1
Gemini0
Very Dissatisfied
GroupValue95% CI
Orion0
Gemini0
Subjective Response for Overall Vision Satisfaction Primary · 2 Weeks - at night

Subjective Response for Vision satisfaction assessed on 7-point Likert (Very satisfied, Satisfied, Somewhat satisfied, Neither Satisfied nor Dissatisfied, Somewhat Dissatisfied, Dissatisfied, Very Dissatisfied)

Very satisfied
GroupValue95% CI
Orion42
Gemini34
Satisfied
GroupValue95% CI
Orion41
Gemini48
Somewhat Satisfied
GroupValue95% CI
Orion8
Gemini10
Neither
GroupValue95% CI
Orion7
Gemini3
Somewhat Dissatisfied
GroupValue95% CI
Orion2
Gemini5
Dissatisfied
GroupValue95% CI
Orion0
Gemini0
Very Dissatisfied
GroupValue95% CI
Orion0
Gemini0
Subjective Response for Overall Vision Quality Primary · Baseline - After 10 minutes of lens dispense

Subjective Response for Overall Vision quality assessed on a 0-100 scale (0- Unacceptable, 100- Excellent Vision)

GroupValue95% CI
Orion90± 8
Gemini91± 9
Subjective Response for Overall Vision Quality Primary · 2 weeks

Subjective Response for Overall Vision Quality assessed on a 0-100 scale (0- Unacceptable, 100- Excellent Vision)

GroupValue95% CI
Orion86± 16
Gemini89± 10
Subjective Response for Overall Vision Quality Primary · 2 weeks - Night Driving

Subjective Response for Overall Vision Quality assessed on a 0-100 scale (0- Unacceptable, 100- Excellent Vision)

GroupValue95% CI
Orion87± 13
Gemini88± 10
Subjective Overall Comfort Satisfaction Secondary · Baseline - After 10 minutes of lens dispense

Overall comfort satisfaction analyzed on 7-point Likert (Very satisfied, Satisfied, Somewhat satisfied, Neither Satisfied nor Dissatisfied, Somewhat Dissatisfied, Dissatisfied, Very Dissatisfied)

Very satisfied
GroupValue95% CI
Orion32
Gemini31
Satisfied
GroupValue95% CI
Orion20
Gemini22
Somewhat satisfied
GroupValue95% CI
Orion7
Gemini6
Neither
GroupValue95% CI
Orion0
Gemini0
Somewhat Dissatisfied
GroupValue95% CI
Orion0
Gemini0
Dissatisfied
GroupValue95% CI
Orion0
Gemini0
Very Dissatisfied
GroupValue95% CI
Orion0
Gemini0
Subjective Overall Comfort Satisfaction Secondary · 2 Weeks

Overall comfort satisfaction analyzed on 7-point Likert (Very satisfied, Satisfied, Somewhat satisfied, Neither Satisfied nor Dissatisfied, Somewhat Dissatisfied, Dissatisfied, Very Dissatisfied)

Very satisfied
GroupValue95% CI
Orion22
Gemini17
Satisfied
GroupValue95% CI
Orion25
Gemini19
Somewhat satisfied
GroupValue95% CI
Orion6
Gemini14
Neither
GroupValue95% CI
Orion0
Gemini2
Somewhat Dissatisfied
GroupValue95% CI
Orion4
Gemini4
Dissatisfied
GroupValue95% CI
Orion2
Gemini3
Very Dissatisfied
GroupValue95% CI
Orion0
Gemini0
Subjective Preference for Comfort Secondary · 2 weeks

Subjective preference for comfort (Orion strongly, Orion slightly, No preference, Gemini slightly, Gemini strongly)

Orion strongly
GroupValue95% CI
Overall Study13
Orion slightly
GroupValue95% CI
Overall Study21
No preference
GroupValue95% CI
Overall Study10
Gemini slightly
GroupValue95% CI
Overall Study7
Gemini strongly
GroupValue95% CI
Overall Study8
Lens Surface Wettability Performance Secondary · Baseline - After 10 minutes of lens dispense

Lens Surface wettability performance was measured on a scale of 0-4, 0.25 steps (0-Very poor, 1 - Poor, 2- Acceptable, 3- Good, 4- Excellent)

GroupValue95% CI
Orion3.40± 0.36
Gemini3.32± 0.40
Lens Surface Wettability Performance Secondary · 2 weeks

Lens Surface wettability performance was measured on a scale of 0-4, 0.25 steps (0-Very poor, 1 - Poor, 2- Acceptable, 3- Good, 4- Excellent)

GroupValue95% CI
Orion3.31± 0.41
Gemini3.40± 0.38
Horizontal Lens Centration Secondary · Baseline - After 10 minutes of lens dispense

Horizontal Lens Centration assessed in primary gaze, white light, diffuse, low-medium magnification, with graticule on 0.1mm steps (Nasal decentration given +ve value. temporal decentration given -ve value)

GroupValue95% CI
Orion-0.12± 0.25
Gemini-0.18± 0.26

Sponsor's own description

The primary objective of the study is to evaluate the clinical performance of test lens (Orion) in comparison with control lens (Gemini) over a period of two weeks of wear.

Publications & conference data

1 peer-reviewed publication reference this trial (live from Europe PMC):

  1. Silicone hydrogel versus hydrogel soft contact lenses for differences in patient-reported eye comfort and safety.
    Haworth K, Travis D, Leslie L, Fuller D, et al · · 2023 · cited 10× · PMID 37724689 · DOI 10.1002/14651858.cd014791.pub2

Verify or expand the search:

Other recruiting trials for Myopia

Currently open trials in the same condition.

Other CooperVision, Inc. trials

Trials by the same sponsor.

Verify against primary sources

Data sources for this page

Drug Landscape aggregates and links these public records for informational use only. Always verify against the primary source before clinical or regulatory decisions. Canonical URL: https://druglandscape.com/trial/NCT04585646.

Primary sources · FDA · ClinicalTrials.gov · EMA · SEC EDGAR · ChEMBL · Wikidata · full sourcing