Last reviewed · How we verify

NCT04242225

Accuracy of Using 2D Transesophageal Echocardiography Compared to Balloon Sizing in Determining Valve Size During Transcatheter Aortic Valve Implantation

Status unknown Last updated 1 September 2020
What this trial tests

trial in Aortic Stenosis, Calcific in 100 participants. Status unknown.

Timeline
1 January 2020
Primary endpoint
1 September 2020
1 October 2020

Quick facts

Lead sponsorAssiut University
StatusStatus unknown
Study typeOBSERVATIONAL
Enrollment100
Start date1 January 2020
Primary completion1 September 2020
Estimated completion1 October 2020
Sites1 location across Egypt

Conditions studied

Sponsor

Assiut University

Who can join

Eligibility, any sex, with Aortic Stenosis, Calcific. Patients with the condition only — healthy volunteers not accepted.

Sponsor's own description

The method of transcatheter aortic valve implantation (TAVI) introduced in 2002 by Alain Cribier et al. has offered new prospects for patients with severe aortic stenosis and multiple comorbidities, who are at high operative risk(1). The PARTNER series of randomized controlled trials has firmly established the role of TAVI with the balloon-expandable Edwards Sapien valve in patients with severe symptomatic aortic stenosis (AS) at prohibitive risk of surgery (PARTNER IA), high risk for surgery (PARTNER IB), and intermediate risk for surgery (PARTNER 2).(2) Also PARTNER 3 and Evolut Low Risk trial strongly suggest that TAVI is not only a suitable alternative and may be superior to surgical aortic valve replacement ( SAVR) in low-risk patients.(2) The accurate determination of the size of the implant is dependent on pre-procedural imaging. Annular measurements are important in the TAVI as inaccurate estimation can lead to complications e.g paravalvular leakage .(3) Transthoracic echocardiography (TTE), transoesophageal echocardiography (TOE), multidetector computed tomography (MDCT) and magnetic resonance imaging (MRI) have been extensively studied with respect to pre-procedural aortic annular sizing.(3). However, even with some of the evidence returning a discrepancy in annular measurements between techniques, the literature to date does not clarify whether TOE undersizes inappropriately or appropriately with respect to MDCT.(3) In a recent study, 29.5% of patients would have been deemed ineligible for TAVI because of overestimation of annular measurements by MDCT, a figure reduced to 1.3% with the use of TOE (4) In a recent small retrospective study, TOE, MDCT and MRI all performed comparatively well with device sizing. (5) Balloon aortic valvuloplasty (BAV) dilatation before TAVI is considered a mandatory procedural step in the early years of TAVR. BAV is used to confirm annular sizing and to enhance trans-catheter heart valve (THV) deliverability.(6) However till now there is no comparison of annular measurement by 2D transesophgeal echocardiography with balloon sizing.

Publications & conference data

No peer-reviewed publications indexed yet for this trial.

Verify or expand the search:

Other Assiut University trials

Trials by the same sponsor.

Verify against primary sources

Data sources for this page

Drug Landscape aggregates and links these public records for informational use only. Always verify against the primary source before clinical or regulatory decisions. Canonical URL: https://druglandscape.com/trial/NCT04242225.

Primary sources · FDA · ClinicalTrials.gov · EMA · SEC EDGAR · ChEMBL · Wikidata · full sourcing