NCT03889847

Comparison of Fiberoptic Bronchoscopic Intubation Between Silicone and Polyvinylchloride Double Lumen Tube.

Completed NA Last updated 20 January 2021
What this trial tests

NA trial testing Fibreoptic intubation with silicone double lumen tube in Intubation;Difficult in 46 participants. Completed in 20 December 2019.

Timeline
25 April 2019
Primary endpoint
19 December 2019
20 December 2019

Quick facts

Lead sponsorAjou University School of Medicine
PhaseNA
StatusCompleted
Study typeINTERVENTIONAL
Allocationrandomized
Designparallel
Maskingdouble
Primary purposeother
Enrollment46
Start date25 April 2019
Primary completion19 December 2019
Estimated completion20 December 2019
Sites1 location across South Korea

Drugs / interventions tested

Conditions studied

Sponsor

Ajou University School of Medicine

Who can join

Adults 19 to 75, any sex, with Intubation;Difficult. Patients with the condition only — healthy volunteers not accepted.

Sponsor's own description

One lung ventilation (OLV) is required during thoracic procedure such as lung and esophagus surgery, and carried out by double lumen tube(DLT). Direct insertion of DLT over a fibreoptic bronchoscope (FOB) is considered more difficult and traumatic than that of a single-lumen tube. Recently, One recent simulation study demonstrated that a soft silicone DLT with a flexible, wire-reinforced bronchial tip (Fuji-Phycon tube) may shorten the time to intubation via tube exchange when compared with less compliant, polyvinyochloride(PVC) DLTs such as the Shilly or Rusch DLT. HumanBroncho® (Insung Medical, Seoul, Korea) is a new silicone DLT with a soft, flexible, non-bevelled, wire-reinforced tip. The oval shape, obtuse angle, and short lateral internal diameter of the bronchial lumen and its flexibility may allow for advancement to the trachea over the FOB easier than the Shilly tube. In the present study, The investigators aimed to test the hypothesis that the silicone DLT would be easier than PVC DLT with regard to railroading grade over an FOB. Investigators further aimed to compare the intubation time over the FOB between the silicone DLT and PVC DLT.

Publications & conference data

1 peer-reviewed publication reference this trial (live from Europe PMC):

  1. Comparison of fiberoptic bronchoscopic intubation using silicone and polyvinyl chloride double-lumen tubes.
    Kang S, Chae YJ, Kim DH, Kim TG, et al · · 2023 · cited 4× · PMID 36577506 · DOI 10.4097/kja.22649

Verify or expand the search:

Other Ajou University School of Medicine trials

Trials by the same sponsor.

Verify against primary sources

Data sources for this page

Drug Landscape aggregates and links these public records for informational use only. Always verify against the primary source before clinical or regulatory decisions. Canonical URL: https://druglandscape.com/trial/NCT03889847.

Primary sources · FDA · ClinicalTrials.gov · EMA · SEC EDGAR · ChEMBL · Wikidata · full sourcing