NCT03650192

INVSENSOR00027 Clinical Performance Study

Completed NA Results posted Last updated 29 January 2021
What this trial tests

NA trial testing INVSENSOR00027 in Healthy in 40 participants. Completed in 18 September 2018.

Timeline
15 August 2018
Primary endpoint
18 September 2018
18 September 2018

Quick facts

Lead sponsorMasimo Corporation
PhaseNA
StatusCompleted
Study typeINTERVENTIONAL
Allocationna
Designsingle group
Maskingnone
Primary purposeother
Enrollment40
Start date15 August 2018
Primary completion18 September 2018
Estimated completion18 September 2018
Sites1 location across United States

Drugs / interventions tested

Conditions studied

Sponsor

Masimo Corporation — full company profile →

Who can join

Adults 18 to 80, any sex, with Healthy. Patients with the condition only — healthy volunteers not accepted.

Results — posted to ClinicalTrials.gov

Per-arm endpoint measurements with 95% confidence intervals where reported. Source: trial results section.

Sensitivity of INVSENSOR00027's Posture Change Detection Primary · 1-5 hours

For each subject's position detection, INVSENSOR00027 output will be compared against observer's notes at each turn of the subject. Correctly detected position changes will be marked as True Positive. Missed detections (if any) will be counted. The sensitivity of INVSENSOR00027's posture change detection will be computed as Sensitivity = True Positive/(True Positive+Missed Detection)

GroupValue95% CI
INVSENSOR00027 Test Group100
Sensitivity of INVSENSOR00027's Activity Change Detection Primary · 1-5 hours

For each subject's activity (e.g., walking and upright) detection, INVSENSOR00027 output will be compared against observer's notes. Correctly detected activity changes will be marked as True Positive. Missed detections (if any) will be counted. The sensitivity of INVSENSOR00027's activity change detection will be computed as Sensitivity = True Positive/(True Positive+Missed Detection).

GroupValue95% CI
INVSENSOR00027 Test Group96.7
Sensitivity of INVSENSOR00027's Fall Event Detection Primary · 1-5 hours
GroupValue95% CI
INVSENSOR00027 Test Group100
Respiratory Rate Detection Secondary · 1-5 hours

Accuracy will be determined by comparing the respiratory rate measurement of the INVSENSOR00027 to the respiratory rate reference (RRef) and calculating the arithmetic root mean square (Arms) value. In order to obtain the Arms value, the RR measurement from the reference is subtracted from the INVSENSOR00027 RR measurement for a number of samples. The average of this difference is computed as the bias. The standard deviation of the differences is computed as the precision. The square root of the sum of the squares of bias and precision is computed as the Arms value.

GroupValue95% CI
INVSENSOR00027 Test Group1.7

Sponsor's own description

This study assesses the investigational sensor's (INVSENSOR00027) performance for detection of subjects' position and posture in bed, along with heart rate and respiratory rate.

Publications & conference data

No peer-reviewed publications indexed yet for this trial. Completed trials usually publish results within 12-18 months.

Verify or expand the search:

Other trials of INVSENSOR00027

Trials testing the same drug.

Other recruiting trials for Healthy

Currently open trials in the same condition.

Other Masimo Corporation trials

Trials by the same sponsor.

Verify against primary sources

Data sources for this page

Drug Landscape aggregates and links these public records for informational use only. Always verify against the primary source before clinical or regulatory decisions. Canonical URL: https://druglandscape.com/trial/NCT03650192.

Primary sources · FDA · ClinicalTrials.gov · EMA · SEC EDGAR · ChEMBL · Wikidata · full sourcing