Last reviewed · How we verify

NCT03405623

Dynamic SAX vs Conventional LAX in Radial Artery Cannulation.

Completed NA Last updated 20 September 2018
What this trial tests

NA trial testing Dynamic needle tip positioning under ultrasound-guidance in Cardiac Surgical Procedures in 146 participants. Completed in 4 June 2018.

Timeline
30 January 2018
Primary endpoint
4 June 2018
4 June 2018

Quick facts

Lead sponsorSeoul National University Hospital
PhaseNA
StatusCompleted
Study typeINTERVENTIONAL
Allocationrandomized
Designparallel
Maskingtriple
Primary purposeother
Enrollment146
Start date30 January 2018
Primary completion4 June 2018
Estimated completion4 June 2018
Sites1 location across South Korea

Drugs / interventions tested

Conditions studied

Sponsor

Seoul National University Hospital

Who can join

19 and older, any sex, with Cardiac Surgical Procedures or Catheterization. Patients with the condition only — healthy volunteers not accepted.

Sponsor's own description

When performing vascular cannulation such as radial artery cannulation, ultrasonography (US) helps proper positioning of the tip of needle in the vascular lumen, which facilitating cannulation of the catheter and successful pressure monitoring. Conventionally, short-axis out-of-plane (SAX) and long-axis in-plane (LAX) views are commonly used method to image the target vessel during cannulation under US guidance. Dynamic needle tip positioning (DNTP) method is newly introduced by one group of investigators who conducted a related study using vascular phantom model. In DNTP, SAX is used, and additionally, when the needle tip is imaged in the screen as an echogenic point, the practitioner (a) proximally moves the US probe a bit, and then (b) the needle is advanced until the needle tip reappears in the screen. In this manner, the practitioner repeats (a) and (b) until the needle is inserted 1 cm into the lumen of vessel, and then the catheter is inserted to finish the procedure. DNTP has not been compared to conventional imaging methods. The aim of this trial is to see the effect of DNTP on success rate of the radial artery cannulation at the first attempt, compared to the conventional LAX.

Publications & conference data

1 peer-reviewed publication reference this trial (live from Europe PMC):

  1. Ultrasound guidance for arterial (other than femoral) catheterisation in adults.
    Flumignan RL, Trevisani VF, Lopes RD, Baptista-Silva JC, et al · · 2021 · cited 11× · PMID 34637140 · DOI 10.1002/14651858.cd013585.pub2

Verify or expand the search:

Other trials of Dynamic needle tip positioning under ultrasound-guidance

Trials testing the same drug.

Other recruiting trials for Cardiac Surgical Procedures

Currently open trials in the same condition.

Other Seoul National University Hospital trials

Trials by the same sponsor.

Verify against primary sources

Data sources for this page

Drug Landscape aggregates and links these public records for informational use only. Always verify against the primary source before clinical or regulatory decisions. Canonical URL: https://druglandscape.com/trial/NCT03405623.

Primary sources · FDA · ClinicalTrials.gov · EMA · SEC EDGAR · ChEMBL · Wikidata · full sourcing