Last reviewed · How we verify

NCT03392766

Fiberoptic Bronchoscope of Double Lumen Tube and Single Lumen Tube in Patients With Semi-regid Neck Collar.

Completed NA Last updated 23 April 2019
What this trial tests

NA trial testing single lumen tube and bronchial blocker in Intubation;Difficult in 80 participants. Completed in 22 April 2019.

Timeline
9 February 2018
Primary endpoint
22 April 2019
22 April 2019

Quick facts

Lead sponsorAjou University School of Medicine
PhaseNA
StatusCompleted
Study typeINTERVENTIONAL
Allocationrandomized
Designparallel
Maskingdouble
Primary purposeother
Enrollment80
Start date9 February 2018
Primary completion22 April 2019
Estimated completion22 April 2019
Sites1 location across South Korea

Drugs / interventions tested

Conditions studied

Sponsor

Ajou University School of Medicine

Who can join

Adults 19 to 75, any sex, with Intubation;Difficult or Thoracic Diseases. Patients with the condition only — healthy volunteers not accepted.

Sponsor's own description

Many intrathoracic procedures demand optimal collapse of the operative lung to facilitate surgical exposure. Single-lung ventilation can be achieved using a double-lumen tube (DLT), a Univent tube, or an independent bronchial blocker. Insertion of a DLT using a direct laryngoscope can be more difficult than that of single-lumen tube (SLT), especially in patients for whom airway difficulty is anticipated. The safest of the proposed methods involves the placement of an SLT with the aid of an fibreoptic bronchoscope (FOB), following which the SLT is replaced with a DLT using an airway exchange technique in these patients. HumanBroncho® (Insung Medical, Seoul, Korea) is a new silicone DLT with a soft, flexible, non-bevelled, wire-reinforced tip. The oval shape, obtuse angle, and short lateral internal diameter of the bronchial lumen and its flexibility may allow for advancement to the trachea over the FOB with as much as ease as a standard SLT. In the present study, the investigators aimed to test the hypothesis that the HumanBroncho® DLT would be non-inferior to a standard SLT with regard to intubation time over an FOB in patients with semi-rigid neck collar simulating difficult airway.

Publications & conference data

1 peer-reviewed publication reference this trial (live from Europe PMC):

  1. Comparison of silicone double-lumen tube and polyvinyl chloride single-lumen tube in fiberoptic tracheal intubation on a difficult airway model: a randomized controlled non-inferiority trial.
    Kang S, Chae YJ, Kim DH, Bae SY, et al · · 2023 · cited 1× · PMID 37225777 · DOI 10.1038/s41598-023-35635-1

Verify or expand the search:

Other trials of single lumen tube and bronchial blocker

Trials testing the same drug.

Other Ajou University School of Medicine trials

Trials by the same sponsor.

Verify against primary sources

Data sources for this page

Drug Landscape aggregates and links these public records for informational use only. Always verify against the primary source before clinical or regulatory decisions. Canonical URL: https://druglandscape.com/trial/NCT03392766.

Primary sources · FDA · ClinicalTrials.gov · EMA · SEC EDGAR · ChEMBL · Wikidata · full sourcing