Randomized, Placebo-Controlled, Double-Blind, Dose Ranging, Single-Dose, 6-Way Crossover Study to Assess Safety, Efficacy and Pharmacokinetics of EP-101 Using eFlow Nebuliser in Patients With COPD
The study assessed the safety and ability of an orally inhaled medicine \[i.e., Glycopyrrolate Inhalation Solution = GIS\] to improve airflow in the lungs when delivered using an eFlow nebulizer in 42 patients with Chronic Obstructive Pulmonary Disease (COPD). Each patient randomly received several, single doses of GIS, or placebo, separated by approximately 1 to 2 weeks. After the dose was given, lung airflow was measured over 24 hours and blood was collected to measure how much GIS was in the bloodstream. The study was conducted to find the once-a- day GIS dose that produced the highest improvement in lung airflow using the eFlow nebulizer.
Details
| Lead sponsor | Sunovion Respiratory Development Inc. |
|---|---|
| Phase | Phase 2 |
| Status | COMPLETED |
| Enrolment | 42 |
| Start date | 2010-07 |
| Completion | 2010-11 |
Conditions
- Chronic Obstructive Pulmonary Disease
Interventions
- Glycopyrrolate Inhalation Solution12.5μg
- Glycopyrrolate Inhalation Solution 50μg
- Glycopyrrolate Inhalation Solution 100μg
- Glycopyrrolate Inhalation Solution 200μg
- Glycopyrrolate Inhalation Solution 400μg
- Placebo 0.5mL
Primary outcomes
- Trough FEV1 (Change From Baseline) — 24hr post dose
Spirometry measurements were conducted in accordance with the current ATS/ERS 2005 guidelines. Trough FEV1 was defined as the mean of FEV1 values obtained at 23 hours 30 minutes and 24 hours post-dose of each Treatment Visit. - Standardized FEV1AUC0-12 Area Under the FEV1 Curve From 0 to 12 Hours Post-dose ( Actual and Change From Baseline). — 0-12h post dose
Spirometry measurements were conducted in accordance with the current ATS/ERS 2005 guidelines.. The standardized actual FEV1 AUC(0-12) was calculated using the trapezoidal rule divided by the actual hours from the first FEV1 to the last FEV1 in the interval. Standardized change from baseline FEV1 AUC(0-12) was also calculated similarly, using the change from pre-dose FEV1. - Standardized FEV1AUC12-24 Area Under the FEV1 Curve From 12 to 24 Hours Post- Dose (Actual and Change From Baseline). — 12-24h post dose
Spirometry measurements were conducted in accordance with the current ATS/ERS 2005 guidelines. The standardized actual FEV1 AUC(12-24) was calculated using the trapezoidal rule divided by the actual hours from the first FEV1 to the last FEV1 in the interval. Standardized change from baseline FEV1 AUC(12-24) was also calculated similarly, using the change from pre-dose FEV1. - Standardized FEV1 AUC0-24 Area Under the FEV1 Curve From 0 to 24 Hours Post-dose (Actual and Change Baseline) — 0 to 24h
Spirometry measurements were conducted in accordance with the current ATS/ERS 2005 guidelines. . The standardized actual FEV1 AUC(0-24) was calculated using the trapezoidal rule divided by the actual hours from the first FEV1 to the last FEV1 in the interval. Standardized change from baseline FEV1 AUC(0-24) was also calculated similarly, using the change from pre-dose FEV1. - Peak FEV1 (Change From Baseline and Percent Change) — 0-4h post dose
spirometry measurements were conducted in accordance with the current ATS/ERS 2005 guidelines. . The peak FEV1 was defined as the highest post-dose FEV1 value within 4 hrs after the dose. Percent change from baseline was calculated as 100 times the difference of peak FEV1 minus baseline FEV1 divided by baseline FEV1.