Last reviewed · How we verify
Head-to-Head Comparison of Endothelial Dysfunction (Bare Metal Stent vs Sirolimus Eluting Stent) in the Same Patient With Multiple Coronary Artery Lesions (CREDENTIAL)
This is a prospective, randomised study to compare the endothelial dysfunction of BMS vs SES, both implanted in the same patient with multiple de novo coronary artery lesions undergoing elective PCI. The primary end point will be the evaluation of endothelial dysfunction at 6 months follow-up by measuring the change in vessel diameter in 5 points of the stent and peri-stent site after infusion of acetylcholine.
Details
| Lead sponsor | Azienda Ospedaliera San Camillo Forlanini |
|---|---|
| Phase | Phase 1/Phase 2 |
| Status | COMPLETED |
| Enrolment | 25 |
| Start date | 2009-03 |
| Completion | 2009-12 |
Conditions
- Endothelial Dysfunction
Interventions
- intracoronary infusion of acetylcholine
Primary outcomes
- evaluation of endothelial dysfunction at 6 months follow-up by measuring the change in vessel diameter in 5 points of the stent and peri-stent site after infusion of acetylcholine — 6 months
evaluation of change in vessel diameters (vasoconstriction or vasodilatation) in proximal and distal stent territories, after intracoronary acetylcholine infusion, having as reference the baseline diameters, for the BMS artery vs the SES artery
Countries
Italy