A Phase 2, Open-Label, Randomized Multicenter Study for the Development of One-Day Rest/Stress Cardiac Positron Emission Tomography (PET) Perfusion Imaging Protocols of BMS747158
The main purpose of this study is to get more information on using BMS747158 (the study drug),a drug with small amounts of radioactivity to allow for heart imaging, during a PET scan which can then be compared to other images such as SPECT. The safety and quality of images will be studied.
Details
| Lead sponsor | Lantheus Medical Imaging |
|---|---|
| Phase | Phase 2 |
| Status | COMPLETED |
| Enrolment | 176 |
| Start date | 2009-01 |
| Completion | 2010-06 |
Conditions
- Ischemia
Interventions
- BMS747158
Primary outcomes
- Cohort 1: Determination of Rest Dose: Dose Acquistion Time Product — Dosing visit
The rest flurpiridaz dose to be used for subsequent efficacy studies was determined by a modeling method that simulated a range of injected doses using a single fixed injected dose at rest in each subject and a range of acquisition durations. From this, a dose acquisition time product (DATP was determined for each subject that specified the minimal dose for a given acquisition duration that yielded an image in that subject that was negligibly affected by photon counting statistics. Descriptive statistics were used to identify an appropriate rest dose for the population. No other statistical tests were performed - Cohort 2: Diagnostic Efficacy of One-day Rest/Stress BMS747158 PET MPI Sensitivity (SN) vs SPECT MPI Sensitivity — Dosing visit
Diagnostic efficacy of one-day rest/stress BMS747158 PET MPI is measured by sensitivity as compared to single photon emission computed tomography (SPECT)MPI in the detection of coronary artery disease (CAD)using angiography or three-month cardiac events as the truth standard. - Cohort 1: Determination of Ratio of Stress Dose to Rest Dose — Dosing visit
The stress flurpiridaz dose for subsequent same-day rest-stress efficacy studies was determined as a multiple of the rest dose by computer modeling. Images derived only from rest flurpiridaz administration were blended using image analysis with images derived only from administration of flurpiridaz following exercise or adenosine stress. The blending fraction that resulted in negligible change in reader interpretation of defect severity was determined for each subject. The minimum value that met this criterion for all subjects was used to calculate the ratio of the stress dose to the rest dose as a function of the delay between administration of the two doses for both adenosine stress and exercise stress separately. No statistical analysis was performed. - Cohort 2: Diagnostic Efficacy of One-day Rest/Stress BMS747158 PET MPI Specificity (SP) vs SPECT MPI Specificity — Dosing Visit
Diagnostic efficacy of one-day rest/stress BMS747158 PET MPI is measured by specificity as compared to single photon emission computed tomography (SPECT)MPI in the detection of coronary artery disease (CAD)using angiography or three-month cardiac events as the truth standard.
Countries
United States